ANSI Lined Pipes (Class 150)
Our pipes are lined, totally strainless, with paste-extruded PTFE and fully automatically tested. Depending on the nominal pipe size, we produce pipes up to a total length of 6 metres.
Materials:
- carbon steel
- stainless steel
Lining materials:
- PTFE (virgin or conductive)
- PP PP (up to nominal pipe size NPS 12“)
Flanges
- fix-loose
- fix-fix
- loose-loose
Other pressure rating:
- Class 300
Special features:
- earthing stud/lug
- vent hole extension
- flange stopper
Optional extras:
- final painting
- non-destructive testing
NPS
| L (mm) | d1
(mm) | d4
(mm) | K
(mm) | smin
(mm) | a1
(mm) | a2
(mm) | No. of bolts x thread (UNC) | Weights | ||
min. | max. | Pipe (ca. kg/m) | Pair of flanges (ca. kg) | ||||||||
½“ | 70 | 6000 | 26.7 | 34.9 | 60.3 | 3.0 | 14.6 | 18.2 | 4 x ½“ | 2.1 | 0.8 |
¾“ | 94 | 6000 | 26.7 | 42.9 | 69.9 | 3.0 | 16.2 | 19.7 | 4 x ½“ | 2.1 | 1.4 |
1“ | 98 | 6000 | 33.4 | 50.8 | 79.4 | 3.0 | 17.7 | 21.3 | 4 x ½“ | 3.0 | 2.0 |
1¼“ | 104 | 6000 | 42.2 | 63.5 | 88.9 | 3.0 | 19.3 | 22.9 | 4 x ½“ | 4.0 | 2.7 |
1½“ | 109 | 6000 | 48.3 | 73.0 | 98.4 | 3.0 | 20.9 | 24.5 | 4 x ½“ | 4.8 | 3.5 |
2“ | 115 | 6000 | 60.3 | 92.1 | 120.7 | 3.0 | 22.5 | 26.6 | 4 x ⅝“ | 6.4 | 5.3 |
2½“ | 126 | 6000 | 73.0 | 104.8 | 139.7 | 3.0 | 25.7 | 30.5 | 4 x ⅝“ | 9.8 | 8.4 |
3“ | 127 | 6000 | 88.9 | 127.0 | 152.4 | 3.0 | 27.3 | 32.4 | 4 x ⅝“ | 12.8 | 10.2 |
4“ | 137 | 6000 | 114.3 | 157.2 | 190.5 | 3.0 | 27.3 | 32.9 | 8 x ⅝“ | 18.1 | 14.3 |
5“ | 159 | 6000 | 141.3 | 185.7 | 215.9 | 4.0 | 28.3 | 34.5 | 8 x ¾“ | 25.1 | 18.2 |
6“ | 163 | 6000 | 168.3 | 215.9 | 241.3 | 4.5 | 30.4 | 37.0 | 8 x ¾“ | 32.8 | 22.6 |
8“ | 182 | 6000 | 219.1 | 269.9 | 298.5 | 5.0 | 34.0 | 41.8 | 8 x ¾“ | 49.2 | 37.3 |
10“ | 188 | 4000 | 273.0 | 323.8 | 362.0 | 7.5 | 38.1 | 47.0 | 12 x ⅞“ | 72.8 | 50.7 |
12“ | 209 | 4000 | 323.8 | 381.0 | 431.8 | 5.0 | 37.2 | 47.1 | 12 x ⅞“ | 84.0 | 77.0 |
14“ | 249 | 3000 | 355.6 | 412.8 | 476.3 | 5.0 | 40.4 | 55.0 | 12 x 1“ | 92.5 | 101.2 |
16“ | 261 | 3000 | 406.4 | 469.9 | 539.8 | 5.0 | 42.0 | 56.6 | 16 x 1“ | 106.2 | 128.9 |
18“ | 280 | 2000 | 457.0 | 533.4 | 577.9 | 5.0 | 45.1 | 59.7 | 16 x 1⅛“ | 119.8 | 144.6 |
20“ | 291 | 2000 | 508.0 | 584.2 | 635.0 | 5.0 | 48.3 | 62.9 | 20 x 1⅛“ | 133.5 | 177.6 |
Nominal pipe sizes over NPS 20“
up to NPS 1000“ on request.
L = Total length
Lmin = Minimum total length with flanges fix-loose
d1 = Outer diameter of the pipe
d4 = Raised face diameter
K = Bolt circle diameter
smin = Minimum flare thickness
a1 = Minimum length with fixed flange and smin
a2 = Minimum length with loose flange and smin
Technical data valid for the pressure rating Class 150.
a1 and a2 depend on construction type and lining thickness.
NPS | Lining thickness | Possible vacuum | |||
standard | thick-walled | 23°C | 150°C | 200°C | |
1“ | |||||
1½“ | |||||
2“ | |||||
3“ | |||||
4“ | |||||
6“ | |||||
8“ | |||||
10“ | |||||
12“ | |||||
= | full vacuum | |
= | limited vacuu | |
= | no vacuum | |
Please refer to the next higher nominal pipe size if your nominal pipe size is not listed. |